Gas chromatograph for analysis of natural gas and biogas
| Application | Suitable to measure the gas components (see table), of which the following is calculated: calorific value, standard density, Wobbe index and relative density |
|---|---|
| The analysis system consists of the components: - analyzing unit with 2 or 3 column modules - analytical computer with archives |
|
| Calculation of calorific value according to ISO 6976 and GPA 2172 | |
| Automatic recalibration | |
| Multistream version for up to 4 gas streams | |
| Windows based operating software RMGViewGC with functions like - viewing, changing and export of parameters - parameter report editor - displaying and saving chromatograms |
|
| Calculation of the methane number (option) | |
| PTB approval pending | |
| Carrier gas | Helium (also for hydrogen measurement) |
| optionally argon as second carrier gas | |
| Inlet pressures | Carrier gas 5.5 bar |
| Measuring gas 1.5 bar | |
| Analytical computer | 19”-module 3 HE (48 TE) |
| Touchscreen | |
| Help texts explaining the parameters | |
| Customer-programmable screen with 20 measured values or parameters | |
| Inputs for external messages (e.g. contact manometers) and measured values (e.g. dew point) | |
| Output signals | Ethernet interface |
| Serial interfaces | |
| DSfG-interface according to DVGW G 485 | |
| Modbus interface | |
| Digital and analog outputs | |