Pipe sizes DN |
Valve seat diameter in mm |
Flow rate coefficient KG* in m³/(h · bar) |
Face-to-face dimension in mm |
|---|---|---|---|
|
25/50 50/100 80/150 100/200 150/300 200/300 |
25 50 80 100 150 200 |
450 1,700 4,600 7,000 15,000 27,000 |
340 380 550 550 750 775 |
|
Setpoint spring |
Specific outlet pressure range Wd in bar |
|||
|---|---|---|---|---|
|
Spring |
Wire Ø in mm. |
Colour coding |
||
|
Control stage |
0 1 2 3 4 5 |
4.5 3.6 4.5 5 6.3 7 |
black blue black grey brown red |
0.3 to 1** 0.5 to 2 1 to 5 2 to 10 5 to 20 10 to 40 |
|
Control stage with metal harmonica measuring unit |
6 7 |
8/7 9 |
green white |
10 to 50 20 to 90 |
|
Automatic load limiting stage |
5 |
green |
0.5 to 15 automatic: above pd |
|
|
Outlet pressure range (pd range) in bar |
Accuracy Class AC |
Lock-up pressure Class SG |
|---|---|---|
|
0.3 to 0.5 > 0.5 to 1 > 1 to 5 > 5 |
20 10 2.5 1 |
30 20 10 5 |
|
Outlet pressure range (pd range) in bar |
Accuracy Class AC |
Lock-up pressure Class SG |
|---|---|---|
|
0.3 to 1 > 1 to 3 > 3 to 5 > 5 to 10 > 10 to 40 > 40 |
20*/30 20 10 5 2.5 1 |
30*/50 30 20 10 10 5 |