DeutschlandGroßbritannienPolenRusslandChina
Serving the Gas Industry Worldwide
RMGSitemapContact usImprint / Legal NoticeDrucken  

Gas pressure regulator RMG 402

Specific outlet pressure range with pilot RMG 620

Pilot

Setpoint spring

Specific outlet pressure range

Wds in bar

Spring
no.

Wire Ø

in mm

Colour coding

Incorporated pilot

2

3

4

5

6

3.6

5.6

6.3

7

8/7

blue

yellow

brown

red

green

0.02 to 0.15

0.1 to 0.5

0.2 to 1

0.5 to 2

1 to 4

Specific outlet pressure range with pilot RMG 630

Setpoint spring

Specific outlet pressure range

Wds in bar

Spring
no.

Wire Ø
in mm

Colour coding

Control stage

0

1

2

3

4

5

4.5

3.6

4.5

5

6.3

7

black

blue

black

grey

brown

red

0.3 to 1*

0.5 to 2

1 to 5

2 to 10

5 to 20

10 to 40

Automatic load limiting stage

5

green

0.5 to 15

automatic: above pd

Specific outlet pressure ranges with pilot RMG 630-1 (formerly RMG 640)

Setpoint spring

Specific outlet pressure range

Wds in bar

Spring
no.

Wire Ø
in mm

Colour coding

Control stage

0

1

2

3

4

5

4.5

3.6

4.5

5.6

6.3

7

black

blue

black

grey

brown

red

0.3 to 1*

0.5 to 2

1 to 5

2 to 10

5 to 20

10 to 40

*) Type with larger measuring diaphragm

Accuracy Class and lock-up pressure Class with pilot RMG 620

Outlet pressure range

(pd range )

Accuracy Class

AC

Lock-up pressure Class

SG

20 mbar to 30 mbar

> 30 mbar to 100 mbar

> 100 mbar to 500 mbar

> 500 mbar to 2.5 bar

> 2.5 bar to 4 bar

10*/20

5*/10

5*/10

5

1

30*/50

20*/30

10*/20

10

10

*) Better accuracy and lock-up pressure classes apply if inlet pressure variation < 8 bar.

Accuracy Class and lock -up pressure Class with pilot RMG 630

Outlet pressure range

(pd range ) in bar

Accuracy Class

AC

Lock-up pressure Class

SG

0.3 to 0.5

> 0.5 to 1

> 1 to 5

> 5 to 90

20

10

2.5

1

30

20

10

5

Accuracy Class and lock -up pressure Class with pilot RMG 630-1 (formerly RMG 640)

Outlet pressure range

(pd range ) in bar

Accuracy Class

AC

Lock-up pressure Class

SG

0.3 to 1

> 1 to 3

> 3 to 5

> 5

20*/30

20

10

2.5

30*/50

30

20

10

*) Better accuracy and lock-up pressure classes apply if inlet pressure variation < 8 bar.

Valve specifications

Pipe sizes

DN 25

DN 50

DN 50/

DN 100

DN 80

DN 80/

DN 150

DN 100

DN 100/

DN 200

KG value* in m³/(h · bar)

350

1300

1500

3500

3800

5200

5500

Face-to-face dimension in mm for:

DIN 

and Class 150 ANSI 16.5

184

254

310

298

400

352

430

Class 300 ANSI 16.5

-

267

310

318

400

368

430

*) Flow rate coefficient for natural gas: (ρb = 0.83 kg/m³, t =15 °C)

Setting range of SSV control element

Actuator system

Overpressure

Wdo in bar

Underpressure

Wdu

0.05 to 1.5

0.4 to 5.2

0.04 to 0.5

0.2 to 1.5

0.6 to 4.5

0.05 to 1.5

0.8 to 40

10 to 120 mbar

60 to 400 mbar

5 to 60 mbar

15 to 120 mbar

40 to 300 mbar

10 to 120 mbar

2 to 40 bar