Valve seat diameter |
5 |
6 |
8 |
12 |
18 |
23 |
|---|---|---|---|---|---|---|
|
Flow rate coefficient |
12 |
25 |
50 |
125 |
200 |
250 |
|
Max. inlet pressure variation Δ pu max in bar (Please consider pressure rating) |
100 |
100 |
100 |
80 |
40 |
25 |
|
Load limiting stage |
Pilot stage |
|||||
|---|---|---|---|---|---|---|
|
Measuring unit |
Wire Ø |
Specific outlet Wds in bar |
Measuring unit |
Wire Ø |
Colour coding |
Specific outlet Wds in bar |
|
M |
3.3 (green) |
0.1 to 1.5 |
N |
2,5 3 3,5 4 5 |
white yellow green red blue |
0.01 to 0.04 0.02 to 0.06 0.04 to 0.12 0.08 to 0.2 0.1 to 0.5 |
|
5 (silver) |
0.5 to 5 |
M |
3,3 4 4,7 |
green blue brown |
0.3 to 1.5 1 to 2.5 2 to 3.5 |
|
|
Setpoint spring |
Specific outlet Wds in bar |
|||
|---|---|---|---|---|
|
Spring |
Wire Ø |
Colour coding |
||
|
Pilot stage with diaphragm measuring unit |
0 1 2 3 4 5 |
4.5 3.6 4.5 5 6.3 7 |
black blue black grey brown red |
0.3 to 1** 0.5 to 2 1 to 5 2 to 10 5 to 20 10 to 40 |
|
Pilot stage metal-harmonica measuring unit |
6 7 |
8/7 9 |
green white |
10 to 50 20 to 90 |
|
Control stage |
5 |
green |
0.5 to 15 automatic: above pd |
|
|
Outlet pressure range (pdrange ) in bar |
Accuracy Class AC with valve seat diameters up to 8 mm |
Accuracy Class AC with valve seat diameters up to 12 mm |
Lock-up pressure Class SG |
|---|---|---|---|
|
0.01 to 0.03 >0.03 to 0.1 >0.1 to 0.5 >0.5 to 1 >1 to 2.5 >2.5 to 5 >5 |
5 5 5 2.5 2.5 1 1 |
10 5*/10 5 2.5*/5 2.5 1 1 |
30 20 10 10 10 10 5 |
*) This better accuracy Class applies if inlet pressure variations are smaller than half the max. inlet pressure pu max.
**) Type with larger measuring diaphragm.
In general, much better values are possible in all outlet pressure ranges.